Please enable JavaScript to view this site.

Knowledge Base

Navigation: Scripting Language > Adding Objects

addheatfluxmonitor

We've made some changes. Use 'Ctrl-F5' to clear your browser cache.
Scroll Prev Top Next More

Adds a heat flux monitor to the HEAT solver region. The monitor can only be added if the simulation environment already has a 'HEAT' solver present.

 

Supported Product: DEVICE

 

Syntax

Description

addheatfluxmonitor;

Adds a heat flux monitor to the simulation environment.

This function does not return any data.

 

Example

The following script command will add a 2D y-normal heat flux monitor to the HEAT solver region and set its dimension.

addheatfluxmonitor;

set("name","heat");

set("monitor type",6);  # 2 = linear x, 3 = linear y, 4 = linear z, 5 = 2D x-normal, 6 = 2D y-normal, 7 = 2D z-normal, 8 = 3D

set("x",0);

set("x span",2e-6);

set("y",0);

set("z",0);

set("z span",10e-6);

 

See Also

Adding Objects, set, addtemperaturemonitor